What was found
INSPECTION TYPE:C2, AFT CARGO BAY, SIDEWALL SUPPORT ANGLE HAS MECHANICAL DAMAGE AT 2 LOCATIONS, BS 1640 BETWEEN STR 24R AND STR 25R. REMOVED DAMAGED SIDEWALL SUPPORT ANGLE. FABRICATED AND INSTALLED REPLACEMENT SIDEWALL SUPPORT ANGLE IAW DWG 453N1603, SRM 51-40-05-0G, SRM 51-40-02-0G, AND MM 51-21-04-7.