What was found
INSPECTION TYPE:C2, THE REPAIR TO THE AFT PRESSURE BULKHEAD VERTICAL BEAM AT LBL 45.70 WL 215 LT SIDE ON AFT SIDE OF BULKHEAD, EO NR B757-5100-36587 REQUIRES THE REPAIR TO BE REMOVED AND REACCOMPLISHED IAW THE SRM. WHEN INSPECTING AREA SURROUNDING REPAIR AREA IAW ESR NR10-2563 4/16/10. FOUND A DENT IN THE 148N2330-3 WEB. REMOVED DAMAGED 148N2330-3 WEB. FABRICATED AND INSTALLED REPLACEMENT 148N2330-3 WEB IAW ER NR 10-2563 DATED 4/30/10, SRM 51-40-02-0G, AND DWG 148N2330.