What was found
INSPECTION TYPE:40, WHILE WORKING FAIRING FORMER ANGLE BRACKET AT BS 1300, STR 21L. FOUND SHEAR TIE ON INSIDE OF SKIN TO BE CRACKED, ALSO NO ALLOWABLE LIMITS PUBLISHED IN SRM. FABRICATED AND INSTALLED REPLACEMENT SHEAR TIE DWG 140N2002 SHT 36/ SRM 51-40-02-0G.