What was found
INSPECTION TYPE:SP, SHEAR TIE BETWEEN STR 14R AND STR 15R AT BS1681 HAS DAMAGE FROM THE FRAME BEING BENT. REPAIRED IAW EO 757-5310-38992-A, SRM51-40-02, ER 10-3727, DATED 02AUG10.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:SP, SHEAR TIE BETWEEN STR 14R AND STR 15R AT BS1681 HAS DAMAGE FROM THE FRAME BEING BENT. REPAIRED IAW EO 757-5310-38992-A, SRM51-40-02, ER 10-3727, DATED 02AUG10.