What was found
INSPECTION TYPE:C3, STIFFENER UPPER SURFACE AT CREW ENTRY DOOR LOWER SILL HAS MECHANICAL DAMAGE AT BS 297.5, LBL 63, WL 215. REPLACED STIFFENER (INNER CHORD ANGLE) IAW SRM 53-10-15-1A1, SRM 51-40-02-0G, DWG 141N8326 SHT 8, SRM 51-30-01-0G, SRM 51-40-05-0G, SRM 51-40-08-0G, SRM 51-20-01-0G, SOPM 20-41-02, AMM 51-31-01-2.