As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
ON DESCENT ELETRICAL "HOT WIRE" SMELL ON CAPTAIN'S SIDE NOTICED. FOUND TOP OF WINDSHIELD HEAT ELEMENT (LWR LT SIDE OF WINDSHIELD) BURNED AND EXTREMELY HOT. DEFERRED IAW MEL 30-41-1-1. DMP ACCOMPLISHED. D435757 ASSIGNED. R & R L1 WINDOW. MM 56-11-01-4. ACCOMPLISHED OPS CHECK OF WINDOW HEAT SYS.