What was found
INSPECTION TYPE:C3, IAW ENGINEERING, FABRICATED NEW FLOOR PANEL FROM BS 333-440 BL 0-RBL 25 AND SCARF FLOOR PANEL IN REWORK AREA. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692-G.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C3, IAW ENGINEERING, FABRICATED NEW FLOOR PANEL FROM BS 333-440 BL 0-RBL 25 AND SCARF FLOOR PANEL IN REWORK AREA. FABRICATED REPLACEMENT FLOOR PANEL IAW EO B757-5320-9692-G.