As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
POS 9L HAS 1/2 INCH BY 1/4 INCH HOLE AND 2ND HOLE .900 BY .600 LOCATED 2.60 INCH AND 5. 50 INCH FROM OTBD EDGE OF PANEL AND 52 INCH FROM FWD EDGE OF PANEL REPAIRED DAMAGE PER 767 SRM 53-00-50-2R. THIS CLEARS D416520 IAW 767B SRM 53-00-50-2R.