What was found
INSPECTION TYPE:PS, REF D438203 POSITION 4 MAIN DECK RT CENTER FLOOR INTERIM REPAIR TO .7500 INCH HOLE IN , 16 INCHES AFT OF FWD LINE. IDENTIFIED FLOORBOARD AS FROM POSITION 4 RT CENTER FLOORBOARD IAW EO B767-5320- 9693H. FABRICATED A REPLACEMENT FLOORBOARD CUTTING OUT A NEW FLOORBOARD USING A402H MARKING INSERT LOCATION USING EXTISTING PANEL AS TEMPLATE. DRILLED AND CLEANED HOLES OF DEBRIS INSTALLED INSERTS, MARKED BOTTOM WITH EO.