What was found
INSPECTION TYPE:8C, FLOOR PANEL FOUND 10 PUNCTURES AND 6 DENTS MARKS AT STA 764 TO 873, LBL 77 TO 88. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-H AND INSTALLED AMM 53-01-01.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:8C, FLOOR PANEL FOUND 10 PUNCTURES AND 6 DENTS MARKS AT STA 764 TO 873, LBL 77 TO 88. FLOOR PANEL FABRICATED IAW EO B767-5320-9693-H AND INSTALLED AMM 53-01-01.