What was found
INSPECTION TYPE:C, CLARIFY THE EXISTING REPAIR CONFIGURATION ON VERTICAL STAB LT LWR AREA CORRELATE TO SRM REPAIR SURVEY SEQ NR 583-S4-01. VERT STAB LT LWR AREA REF SURVEY SEQ 583-S4-01 METAL HOT BOND REPAIR PERFORMED IAW SRM 51-70-10-2R REPAIR4 FIG201 SHT3. THIS IS CLASSIFIED AS MAJOR REPAIR. REPAIR DOUBLER SIZE 6" X 7.375". FINAL CUTOUT SIZE 3" X 4.375" LOC: VERT STAB LT LWR AREA FIN STA260. REF RS R55-35-36943 & EO B747-5530-41599 FOR REPEAT INSPECTION.