What was found
INSPECTION TYPE:C2, FWD CARGO BAY RT FLOOR TO SIDEWALL SUPPORT IS CORRODED AT BS 780 TO BS 820 AROUND TIE DOWN LOCATIONS. R & R FLOOR TO SIDEWALL PANEL IAW SRM 51-40-02, 51-40-06, 51-20-01 AND AMM 51-20-00-0.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C2, FWD CARGO BAY RT FLOOR TO SIDEWALL SUPPORT IS CORRODED AT BS 780 TO BS 820 AROUND TIE DOWN LOCATIONS. R & R FLOOR TO SIDEWALL PANEL IAW SRM 51-40-02, 51-40-06, 51-20-01 AND AMM 51-20-00-0.