What was found
INSPECTION TYPE:C2, NR 2 ENG. NACELLE STRUT AFT FAIRING AREA. LT-ANGLE CRACKED ON HORIZONTAL FLANGE, LOCATED AT AFT LWR CORNER OF CUTOUT FOR PANEL 445AR (MARKED). R & R LT-ANGLE BRACKET IAW SRM 51-40-02-0G STEP 7D (1)- 6).
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:C2, NR 2 ENG. NACELLE STRUT AFT FAIRING AREA. LT-ANGLE CRACKED ON HORIZONTAL FLANGE, LOCATED AT AFT LWR CORNER OF CUTOUT FOR PANEL 445AR (MARKED). R & R LT-ANGLE BRACKET IAW SRM 51-40-02-0G STEP 7D (1)- 6).