What was found
INSPECTION TYPE:C2, NR1 ENG NACELLE STRUT AFT FAIRING AREA, OTBD HAT CHANNEL SUPPORT HAS DAMAGE ON VERT FLANGE. LOCATED AT FWD SIDE OF CUTOUT FOR PANEL 435AL (MARKED). R & R NR1 ENG AFT FAIRING 435AL OTBD LOWER CHORD IAW SRM 51-40-02 SRM 54-51-71-01-1, SRM 54-51-71-1A-1 DWG 313N3050.