What was found
INSPECTION TYPE:MX POS 4 FLOORBOARD MCD CENTER INTERIM REPAIR 2 INCH HOLES 16 INCHES AFT OF CENTERLINE IDENTIFIED PANEL FROM POSITION 4. PN 143T5876-98 IAW EO B767-5320-969 APPENDIX H. FABRICATED A REPLACEMENT PANEL BY CUTTING OUT A NEW PANEL FROM A402H AND MARKING INSERT LOCATIONS USING EXISTING PANEL AS TEMPLATE. DRILLED AND CLEANED HOLES OF DEBRIS. INSTALLED INSERTS USING BMS 5-107 AND CURED FOR 12 HOURS.