What was found
INSPECTION TYPE:D, NWW RT SIDE PANEL, 1 EA STIFFENER FOUND CRACKED BETWEEN BS 280-330 AT WL 180, CRACK LENGTH APPROX .1250" LONG FROM STIFFENER FWD EDGE. STIFFENER REPLACED AND INSTALLED IAW SRM 51-10-02 AND 51-40-02 REV 58 AT BETWEEN BS 280-300 AT WL 180 AREA.