What was found
INSPECTION TYPE:D, M/D STA 960, LT CREASE BEAM TO FRAME ATTACH ANGLE CRACKED AT STR 7L AREA M/D, STA 960, LT CREASE BEAM TO FRAME ATTACH ANGLE AT STR 7L AREA. REPLACED AND INSTALLED IAW HX RS R-53-20-37044, REV A AND EO B747-5310-42616-A. THIS IS A CATEGORY REPAIR & CLASSIFIED AS MINOR REPAIR. REPETITIVE INSPECTIONS WILL BE ACCOMPLISHED IAW EO B747-5310-26850.