What was found
ELECTRICAL SYS CYCLING ON & OFF, CAUSING AUTOPILOT DISCONNECT, SPOILER FAULTS, AND PITCH COMPUTER FAULTS. MOST SYS RESET BUT FAILED AGAIN. LIGHTS INSIDE CHANGED AS WELL. DECLARED EMERGENCY. R & R NR 2 IDG, & R & R NR 1 GCU. FOUND IDG WIRE HARNESS WITH FRAYED WIRES. R & R WIRE HARNESS. PERFORMED OPS CHECK OF NR 2 IDG. OPS CHECKED GOOD IAW MM 24-11-00-0501.