What was found
INSPECTION TYPE:C, MAIN DECK FLOOR PANEL 231XJF EDGE HAS DAMAGE. DOT 15-035, PANEL RACK. FABBED PANEL 231XJF, PN 143N5457-95 FROM A402H-48X144, BAT 2664589 STEP CUT ACCOMPLISHED IAW SREO 5320-9692-H. RESTORE LOWER SURFACE IAW SREO 5320-9692-H. FABRICATED REPAIR PLYS USING BMS 9-3 BATCH 2357605 IAW EO 5320-9692-H AND SRM 53-00-50-2R-1. OK TO BOND FIBERGLASS OVERLAYS. APPLIED FIBERGLASS PLYS ON STEPS CUTS VAC.