What was found
INSPECTION TYPE:C, MAIN DECK FLOOR PANEL 231XJF IS DELAMINATED. PANEL RACK 1. FABBED 231XJF FROM A402H-48X144, BATTERY 0664589 IAW SREO 5320-9692-H APPEN B1, 2. BOND REINFORCING PLIES IAW SREO B757-5320-9692-H APPEN B 2. SCUFF SANDED AND PREP OT THE BONDING AREA IAW EO OO B757.