What was found
INSPECTION TYPE:C, MAINTENANCE REQUIRED, MAIN DECK CREW ENTRY FLOOR PANEL 211XAF IS DELAMINATED. PANEL RACK1, FABBED 211XAF FROM A402H-48X144, BATTERY 2664589 IAW SREO B757-5320-9692-H APPEN B. BOND REINFORCING PLIES IAW SREO B757-5320-9692-H APPEN B. SCUFF SAND AND CLEANED THE AREA TO BE BONDED IAW EO B757-5320-9692-H AND SRM 53-00-20-2R.