What was found
EMERGENCY DECLARED, FIRE DETECTOR 1 FAIL ILLUMINATED INTERMITTENTLY, CHECK FOUND TB2 TERMINAL BLOCK CRACK, LOWER TURBIN DETECTOR SHORT TO GROUND, LOOP B DH8 TO DH9 WIRE SHORT TO GROUND, IAW WDM 26-11-01, AMM 26-11-03, AMM 26-11-02, RPL TB2, LOWER TURBINE DETECTOR , LOOP B, DH 8 TO DH 9 WIRE AND FCDU 1 TEST PASS, NO FAULT FOUND, PN ON: 224W9932-501.