What was found
BLEED 1 EICAS, BLEED OVER PRESSURE 1, STATUS FRAME 36105900, FUEL DUMP 80.000 LBS, FOUND BLEED-1 PRESSURE REGULATING VALVE, CONTROLLER FAIL OPEN MSG 36226. DEFERRED NR 1 ENGINE PRV SYSTEM IAW MEL 36-11-8-3. R&R NR 1 ENG PRV AND PRVC PER MM 36-11-20 AND 36-11-10. NO DEFECTS NOTED. OPERATED ENG TO T/O POWER FOR 3 MINS. NO NR 1 ENG BLEED FAULTS. THIS CLEARS M580665. PLACARD REMOVED.