What was found
EMERGENCY DECLARED DUE TO LE SLAT DISGREE LIGHT AND EICAS MESSAGE . RAN CHECKLIST BUT LEADING EDGE LIGHT REMAINED ILLUMINATED. USED ALTERNATE FLAPS SWITCH TO GET TE FLAPS TO 20 FOR LANDING. PERFORMED FIM 27-81-00-815-803 BLOCKS 1A THRU 1D AND BLOCK 28, WITH NO FAULTS, OPERATED FLAPS AND SLATS NUMEROUS TIMES, BOTH HYDRAULICALLY AND ELECTRICALLY . OK TO CONTINUE. OPS CHECKED NORMAL