What was found
INSPECTION TYPE:N/AEMERGENCY DECLARED - ACCU PRESS NORMAL, LEFT SIDE PRESS 0, RIGHTSIDE PRESS 3000 IN CRUISE, BRK/A SKID SWITCH NORM/ONCLEANED CONNECTOR ON 72GG, 73GG YELLOW BRAKE PRESSURE TRANSMITTERS. PERFORMED ALTERNATE BRAKING SYSTEM OPERATIONAL TEST PER AMM 32-43-00 PG BLK 0501. OPS CHECKS NORMAL. OK FOR CONTINUED SERVICE.