What was found
INSPECTION TYPE:3CCENTER CARGO COMP MRH INTERCOSTAL UNDER Z-FRAME BETWEEN STA 5-11 AND 5-32 HAS A CRACK AT FWD SIDE.REMOVED, FABRICATED AND INSTALLED INTERCOSTAL IN CENTER CARGO COMP BETWEEN STA 5-11 - 5-32. IAW SRM 51-33-01. (MINOR)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:3CCENTER CARGO COMP MRH INTERCOSTAL UNDER Z-FRAME BETWEEN STA 5-11 AND 5-32 HAS A CRACK AT FWD SIDE.REMOVED, FABRICATED AND INSTALLED INTERCOSTAL IN CENTER CARGO COMP BETWEEN STA 5-11 - 5-32. IAW SRM 51-33-01. (MINOR)