What was found
INSPECTION TYPE: N/A ATB, AC OOS. NO EMERGENCY WAS DECLARED, LANDED W/OUT INCIDENT. FOUND DAMAGE ON NR 12 SLAT LEADING EDGE. C/W NR 12 SLAT LEADING EDGE DENT/GOUGE REPAIR, REF EO B767-5750-78560-A AND M/M 57-43-01-1A TEMP REPAIR. OK TO CONTINUE.