What was found
INSPECTION TYPE: N/A EMERGENCY DECLARED. LANDED UNEVENTFULLY. LEADING EDGE SLAT DISAGREE ON APPROACH, OCCURED LESS THAN FLAPS 1, RAN QRH CHECKLIST AND LANDED FLAPS 20. PERFORMED T/S, PER FIM REF 27-81-00 FOUND NR 10 ROTARY ACTUATOR OVERLOAD INDICATOR TRIPPED, R & R NR 10 ROTARY ACTUATOR, PER MM REF 27-81-18. OPERATIONS CHECKS GOOD, OK FOR CONTINUED SERVICE. EFF SOURCE REF: IPC 27-81-18-01.