What was found
INSPECTION TYPE: NA AFTER CLOSING THE CREW ENTRY DOOR AND ARMING, THE BELL SOUNDS BUT THE LIGHT DOESN`T ILLUMINATE. DEFERRED EVACUATION SLIDE WARNING SYSTEM LIGHT, IAW MEL 52-73-01-1. INSTALLED PLACARD. R & R'D LIGHT ASSEMBLY AND C/B, IAW 52-73-11. OPERATIONS CHECK GOOD. M731253 IS CLOSED. PLACARDS REMOVED.