What was found
INSPECTION TYPE:3C#1 MAIN FUEL TANK STRINGER 38 CLIP IS CRACKED AT STA XORS 506.REMOVED AND REPLACED CRACKED #1 MAIN FUEL TANK STRINGER CLIP AT STA XORS 506 IAW SRM 51-33-01. (MINOR)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:3C#1 MAIN FUEL TANK STRINGER 38 CLIP IS CRACKED AT STA XORS 506.REMOVED AND REPLACED CRACKED #1 MAIN FUEL TANK STRINGER CLIP AT STA XORS 506 IAW SRM 51-33-01. (MINOR)