What was found
INSPECTION TYPE:NAWHILE PREFORMING TC-9197 EVAS TEST BOTH LH AND RH EVAS UNITS FAIL BLOWER TEST. WILL NOT RUN. MANUAL SWITCH ON CKS OK. ACCOMP. DMP 25-68-1 REMOVED AND PROCESSED. DEFERRED UNDEER MEL 25-68-1 CONTROL NUMBER M747080. PLACRD INSTALLED.INSTALLED NEW EVAS BOXES ON CAPTAIN & COPILOTS SIDES OF SEATS. IAW AMM 05-69-00, OPS CHECK GOOD. M747080 CLOSED. DMP REVERSED, PLACARD REMOVED. ESR IAW 25-60-00-90-001 & 002.