As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
INSPECTION TYPE:3CRT I/B ELEVATOR I/B L/E RIB UPPER FLANGE AT XE= 125.8 IS CRACKED.REPAIRED CRACKED RT I/B ELEVATOR I/B L/E RIB UPPER FLANGE AT XE= 125.8 IAW VT-SAA EA 011-5520-01-A9301 REV. IR AND UPS EO MD11-5520-81471-A. REF. FAA FORM 8100-9 SIGNED BY P. LAU (AR-830967) DATED 08/30/2021 (MAJOR)