What was found
INSPECTION TYPE:N/A** SUPPLEMENTAL SDR ** L1 DOOR DOES NOT WORK FROM INSIDE SWITCH. DEFERRED IAW MEL 52-10-3-1-2-1-2. L1 DOOR DOES NOT OPEN/CLOSE ELECTRICALLY.T/S PER WDM 52-11-01, FOUND GIRT BAR SWITCH S1-1090 STICKING, FREED UP SWITCH & PERFORMED OPS CK PER AMM 52-10-01-700-801. THIS CLEARS M768045, PLACARD REMOVED.