INSPECTION TYPE:NA**SUPPLEMENTAL SDR**L1 DOOR WILL NOT OPEN ELECTRICALLY. DEFERRED PER MEL 52-10-3-1-2-1-2. M768556 ASSIGNED, PLACARD INSTALLEDREPLACED S2-730 LOCK REL SOL, R2-177 DOOR ACT RELAY PER AMM 52-10-06 & 20-30-00 W/ REF IPC 52-34-01-01-911. RAN ALL WIRING PER WDM & LAMM 52-11. FOUND OPEN CIRCUIT AT C/P P1-385 PINS A & B LEVER ACT SW S1-211. REMOVED DEBRIS FROM BEHIND COURIER SEATS & FULLY STOWED SEAT ASSY CLOSING SEAT OPS CK GOOD. PER AMM 52-10-01. CLEARS M768556. PLACARD RMVD.