What was found
INSPECTION TYPE:SEG2FLOOR BEAM AT STA 1100 LBL4 HAS CORROSION OUT OF LIMITS. ORIGINAL THICKNESS .200" MATERIAL REMAINING .140" MATERIAL LOSS .060"REPLACED SECTION OF UPPER FLANGE FROM RBL 13.0 TO LBL 12.0 PER EO B757-5310-27-A2990
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE:SEG2FLOOR BEAM AT STA 1100 LBL4 HAS CORROSION OUT OF LIMITS. ORIGINAL THICKNESS .200" MATERIAL REMAINING .140" MATERIAL LOSS .060"REPLACED SECTION OF UPPER FLANGE FROM RBL 13.0 TO LBL 12.0 PER EO B757-5310-27-A2990