What was found
INSPECTION TYPE:DIRH LOWER FUSELAGE AT STA 700, S-24R HAS A TEMPORARY LIGHTINING STRIKE REPAIR. REQUIRES PERMANENT REPAIR. SKIN P/N: 143N3691-2, ORIGINAL MAT: STOCK 0.080" THICKNESS, 2024-T3 CLAD SHEETACCOMPLISHED REPAIR PER 757-200PF SRM REV 114.0, CHAPTER 53-00-01-2R-28 PER SRM 53-30-01-2R1