What was found
INSPECTION TYPE:NA**ATB**AT APPROXIMIMATELY 3000FT, ON DEPARTURE "TAT PROBE" EICAS MESSAGE AND FAILURE.REPLACED TAT PROBE PER AMM 34-12-02-404-008, BUT SAME CONDITION. REPLACED CURRENT SENSING RELAY PER WDM 30-33-11 SHEET1, TAT PROBE HEAT SYSTEM OPERATION TEST OK PER AMM 30-33-00-715-010.K.ISHITANI NRT4921