What was found
IMMEDIATELY AFTER TAKE OFF HAD "WET SOCK" SMELL IN COCKPIT. LASTED APPROX 30 SECONDS. PACK 1 OPERATING SE E PREV WRITE UP LOG PAGE 225135 ALSO SEE PREVIOUS LOG PAGE 225134 FOR #1 ENG"OIL WETTING EVIDENT IN INLET COWL COWL " AGAIN DURING DESUNABLE TO DUPLICATE "WET SOCK SMELL" ON GROUND. AD PRECUATIONAR SERVICED #1 PACK WATER SEPERATOR AS PER MM CHPTR 21-1-16. RAN PACK PACK FOR PERIOD OF TIME AS PER MM CHPTR 21-11-00 NO ISSUES NOTED. C/W CK NO 13 OIL LK CK. NO FURTHER ISSUES NOTED. OK TO CONT SERVICE REF A300 TSM 72-00-40