What was found
INSPECTION TYPE:NA*SUPPLEMENTAL SDR* *ATB* *EMER DECL* ON CL RECEIVED & ADVISORY ON ENG A2 (RT.) FOR LOW OIL QTY. WE VERIFIED THE QTY READING ON THE MANUAL GUAGE - BOTH ENG MAIN TIR AND GAUGE INDICATED 1 QT REMAINING ELECTED TO RTRN TO BASE LANDED 15/20, TXIED CLR AND SHUT. DEFD PER MEL 79-31-01-2 DMP 79-31-01-2 C/W #2 ENG OIL QTY VERIFIED FULL, NO EXT LEAKS NOTED.R&R #2 OIL QUANTITY TRANSMITTER IAW A300 AMM 79-31-11 OPS CHECK SAT THIS CLEARS M 800397 PLACARD REMOVED