What was found
FAULT: CREW DOOR EMERGENCY EXIT LIGHT DID NOT ILLUMINATE. INSTALLED SERVICEABLE EXIT LIGHT BATTERY, PN: 2013-1A, SN: 64053 AND OPS CHECK GOOD IAW B757 AMM 33-51-07-902-001. REVIEWED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FAULT: CREW DOOR EMERGENCY EXIT LIGHT DID NOT ILLUMINATE. INSTALLED SERVICEABLE EXIT LIGHT BATTERY, PN: 2013-1A, SN: 64053 AND OPS CHECK GOOD IAW B757 AMM 33-51-07-902-001. REVIEWED.