What was found
DURING OPERATIONAL CHECK OF ESCAPE SLIDE WARNING LIGHT AND ANNUNCIATOR, BOTH THE LIGHT AND ANNUNCIATOR ARE NOT WORKING. PERFORMED FAULT ISOLATION IAW AMM 52-73-01 PAGE 5, DURING THE WIRING CHECK THE GROUND LINE IN THE TERMINAL BLOCK 6035VT CONTACT "B" FOUND UNLOCK , THE CONTACT "B" LOCKED IAW ESPM 20-48-20-02, OPS CHECK GOOD IAW AMM 52-10-00/301.