What was found
DISBOND FOUND RUDDER R/H SPAR AND ADJACENT STRUCTURE BETWEEN RUDDER STATION 106 AND STATION 181. (REPAIR). REPAIR DELAMINTION ON RH RUDDER SKIN PANEL AT RUD STA 140.108 I.A.W. UPS EO-92480-REQ1 REV1. CONDITION CHECK IS SATISFACTORY.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DISBOND FOUND RUDDER R/H SPAR AND ADJACENT STRUCTURE BETWEEN RUDDER STATION 106 AND STATION 181. (REPAIR). REPAIR DELAMINTION ON RH RUDDER SKIN PANEL AT RUD STA 140.108 I.A.W. UPS EO-92480-REQ1 REV1. CONDITION CHECK IS SATISFACTORY.