What was found
MAJOR REPAIR, IMPACT DAMAGE TO FUSE. SKIN STA. 1340 STR. 25L (REFERENCE SRM 53-60-01-0I-1, FIGURE 1, DETAIL II, ITEM 2). THE DAMAGE CONSISTS OF A DENT TO THE FUSELAGE SKIN PANEL. THE DENT MEASURES APPROXIMATELY 10.5IN CIRCUMFERENTIALLY BY 2.0IN FWD/AFT WITH A MAXIMUM DEPTH OF 0.088IN. THE DENT IS LOCATED AT STA 1340 AND S-25L. WITHIN THE PERIPHERY OF THE DENT IS A GOUGE. AFTER BLENDING THE GOUGE, THE AREA MEASURES 3.6IN CIRCUMFERENTIALLY BY 0.9IN FWD/AFT AND A HAS A MINIMUM REMAINING SKIN THICKNESS OF 0.0546IN. REFER TO FIGURE 1 FOR DAMAGE LOCATION. OPEN