What was found
NUMBER 6 SLAT O/B END LWR LEADING EDGE LWR SURFACE CLOSING PLIE HAS A CRACK AS MARKED. INSTALLED CLOSING PLIE IAW SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
NUMBER 6 SLAT O/B END LWR LEADING EDGE LWR SURFACE CLOSING PLIE HAS A CRACK AS MARKED. INSTALLED CLOSING PLIE IAW SRM 51-40-02.