What was found
FOUND CRACK-ANGLE, BULK CGO COMPT CEILING AREA, STA 1577 RBL 74 OUTBD SIDE. I.A.W AMM 25-59-01-004-001 REV.146 REMOVED DADO PANEL AND G.V.I CHECK NORMAL. REMOVED DAMAGE ANGLE I.A.W SRM 51-40-02-0G REV. 93. INSTALLED NEW ANGLE I.A.W SRM 51-40-02-0G REV. 93 AND BOEING DWG NO. 146T5650 SH. 5 REV. C. PERFORM DADO PANEL OK TO CLOSE CHECK AT STA 1578 R/H SIDE. INSPECTION CHECK OK. I.A.W AMM 25-59-01-404-019 REV.146 INSTALLED DADO PANEL. CONDITION CHECK NORMAL.