What was found
FOUND CRACKED ANGLE, BULK CGO COMPT CEILING AREA, BS 1577, LBL 74, INBD SIDE. (REPLACE) INSPECTION COMPLETED FOR MAIN DECK CARGO INSPECTION OF FLOOR PANEL OK TO INSTALL CHECK AT STA 1540 ~ 1599 , LBL54 ~ 88 , PANEL NO.251CGF, DADO PANEL AT STA 1578 L/H (NO.251QSF , 251PSF) I.A.W AMM 53-01-06-400-801 REV.146 INSTALL MAIN DECK CARGO FLOOR PANEL AND CONDITION CHECK NORMAL. 2. I.A.W AMM 25-59-01-404-019 REV.146 INSTALL MAIN DECK CARGO DADO PANEL AND CONDITION CHECK NORMAL.