What was found
MAIN DECK FLOOR FITTING WAS DAMAGE AT BS 1109, BL 0. REMOVED DAMAGE FITTING IAW SRM 51-40-02-0G REV 93.2. INSTALLED NEW FITTING IAW SRM 51-40-02-0G REV 93, AND DWG 457T4000, SHEET 11, REV B.3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
MAIN DECK FLOOR FITTING WAS DAMAGE AT BS 1109, BL 0. REMOVED DAMAGE FITTING IAW SRM 51-40-02-0G REV 93.2. INSTALLED NEW FITTING IAW SRM 51-40-02-0G REV 93, AND DWG 457T4000, SHEET 11, REV B.3.