What was found
MAJOR REPAIR, DEBONDED, PREVIOUS REPAIR, L/H WING NO.5 SLAT UPPER SURFACE LES 440. CUT OUT THE DAMAGE MATERIALS AND CLEAN, MEASURE THE CUTOUT SIZE (L:5.75", W:5.25", 38" FROM INBD EDGE AT AFT EDGE OF THE LT WING NR 5 SLAT UPPER SURFACE LES 440) IAW SRM 57-43-02-2R-1, REFER TO SRM 51-70-10-2R-4 AND SRM 51-70-10-2R-0 PARAGRAPH 6 & 7 REV.94. IAW AMM 27-81-02-424-099, REV 147 STEP 3.A TO H(12), H(15) & H(16). INSTALLED NR 5 SLAT IAW AMM 27-81-02-424-099, REV.147 STEP H(13),(H14), INSTALLED NR 5 SLAT CTRL ROD IAW AMM 27-88-01-722-028, REV 147. ACCOMPLISHED LEADING EDGE SLAT SENSOR TEST.