What was found
DENTED INNER BARREL, NR 2 ENG INLET COWL INNER AT THE 12 O'CLOCK POSITION. CUT OUT THE DAMAGE AND CLEAN, MEASURE THE CUT OUT ( DIA : 0.4", 13" FROM AFT EDGE AND 13" FROM INBD EDGE, AT 12 O'CLOCK ON THE INNER BARREL OF NO.2 ENG INLET COWL ). FILL THE CUT OUT WITH ADHESIVE CURED AT 200°F FOR 1 HOUR IAW SRM 54-15-01-2R-3, REV. 95. CONDITION CHECK IS SATISFACTORY. THE CUMULATIVE REPAIR BLOCKAGE OF ACOUSTIC PANEL IS 0.13 SQUARE INCHES FOR THIS NRC. THE CUMULATIVE REPAIR BLOCKAGE OF ACOUSTIC PANEL IS 0.13 SQUARE INCHES FOR NR 2 ENGINE INLET COWL CONFIRM THAT THE ENGINE NACELLE IS ACOUSTICALLY COMPLIANT IAW SRM 54-00-00-2R-0 REV. 95.