What was found
L3 WINDOW BURNED AT TEMP CONTROL SENSORS. CREW REPORTED BURNING SMELL PRIOR TO WINDOW CRACKING. REF BARCODE [T3F18E008X3R6] FOR WINDOW REPLACEMENT. R+R RIGHT FORWARD AND LEFT SIDE WINDOW HEAT CONTROL UNIT, WHCU M192 PER AMM 30-41-02/401. OPS CHECK GOOD.